![]() Meade Telestar Reflecting Refracting Telescopes DS-2114ATS Autostar LOOK MINT 285.00. (The LX90 PCB layout is very close to the ETX125s except the voltage of ETX is 12V vs. Meade ETX-70AT Digital 70mm Refractor Telescope w AutoStar Controller Extra Lens. #Meade autostar voltage serial#The serial port signal is routed from the AutoStar box to the base of the scope and then to the top of the right arm of the fork to accept the BlueTooth transmitter for. If MyScope can do that, communications with the PC are working. Meade ETX 125 Telescope Heavy Electrical. Can *it* find the scope on the COM ports? If so, it will be able to fetch a bunch of the operating info from the scope. connect the scope-to-PC cables and start up his program (MyScope). Next test (do the above first): After you've entered the time and date does the scope just sit there properly? (from your earlier note it sounds like it does) Load Andrew's MyScope app into your PC. #Meade autostar voltage code#and the motor control when it's NOT trying to download uses different areas of the firmware than the Downloading code invokes. Now turn on the scope and manually provide the date and time (you can do this in the day, but give it "night" times and work from memory or star charts "what's up") and *then* try to GoTo (or Align) : Does it operate properly? (this is a test of the motor boards under "full control") Do the alignment slews (and the after-aligning sidereal drive) operate properly? (no run-aways) ((if you are doing daytime testing, just tap ENTER to accept each alignment star)) I'm trying to have you "walk through" various zones of the programming. If you turn Settings/Telescope/GPS Align to "OFF" (enter) Then turn off the scope. ![]() Let's approach this one (quite comprehensive) step at a time. i've read back through the thread to see the original complaint. #Meade autostar voltage software#I don't recall the software path behind that sensor board check, but it's possible that if you turn OFF the GPS alignment and turn off Auto Align (choose One Star or Two Star) that the scope will ignore the lack of that board (if you don't ask for its services, it won't try to find it). Sometimes simply re-seating those connectors can clear up problems like this. Another possibility is that the cable coming from the Autostar (the board behind the power panel) may have become loose (or its connector pins oxidized) at the Autostar end. The flat cable wrapped around the DEC axle can crack with age and flexing. ![]() Remove the cover: That reveals the cards. You access that area by removing the "knob" at the axis (it can can be simply unscrewed), then the metal disc beneath it, and the bunch of allen screws running around the fork's edges that secure the cover plate. Frequently problems with that are due to the wiring becoming loose or damaged. controller cable Brief Description Meade 497 Autostar compatible Replacement cable for Autostar is straight and will not pull you back to the telescope like the original coiled cable. The auxiliary sensor board is located in the "left" fork (the one with the GPS lump on top). Meade Aftermarket 497 Autostar replacement hand. On Sun, at 07:25 AM, Rupert Duringer wrote: Autostar just tells me there is no auxiliary sensor board and says to send back to factory :Īh. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |